Product Selector Tool Results: 22 Product(s)

Number of channels

Housing width

Input

Output

Functions

Supply

Safety Integrity Level


Choose your product


Next PageLast Page
Product

1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa
1-channel isolated barrier, 24 V DC supply (bus powered), Analog input, digital input,
analog output, digital output, No configuration required, device is self-adapting, HART transparency, Low power dissipation, 3-way isolation, Up to SIL 2 acc. to IEC 61508 in preparationpa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC bus powered via Termination Boardpa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC bus powered via Termination Boardpa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC bus powered via Termination Boardpa
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508pa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508pa
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508pa
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC bus powered via Termination Boardpa