Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Multiple-Beam Light Barriers


Narrow down search result list

Product Selector Tool Results: 256 Product(s)

Resolution

Number of Beams

Protection Field Height

Max. Detection Range

Operating Mode

Safety Output

Connection Type

Safety Type

Safety Integrity Level

Performance Level


Choose your product


Next PageLast Page
Product
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Slim design, mounting on three sides, Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m
, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mmfa
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 60 mm , Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 90 mm, Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mmfa
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 60 mm , Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 90 mm, Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light gridsfa
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light gridsfa
Next PageLast Page